Run and start capacitors
Carried across the common microfarad and voltage ratings for both single and dual capacitors. The most frequent single cause of a cooling failure and a part that costs very little.
A person answers, triages the fault and prices the visit before anybody is sent. Whoever knocks on the door at three in the morning brings the identical instrument set, credentials and van inventory as the weekday crew.
Cooling equipment fails under load, which means it fails on the hottest afternoons and the closest nights rather than on a mild Tuesday when it would be convenient. A compressor that has started ten thousand times without complaint will refuse on the eleven thousand and first because the capacitor feeding it has quietly drifted below its rating over three seasons.
What matters at that point is whether the company you call can actually finish. An emergency visit that ends in a diagnosis and a return trip on Thursday has solved nothing for a household sitting in a building that will not cool. The parts inventory carried on the van is the difference, and it is chosen from what actually fails rather than from what is cheap to stock.
There is also a category of emergency that is not an equipment fault at all. A condensate drain that plugged gradually through the summer trips a float switch and shuts the whole system down deliberately, which from inside the house is indistinguishable from a dead compressor. A thermostat whose batteries died overnight does the same thing. Both get ruled out in the first few minutes precisely because they are cheap, common and embarrassing to miss.
Work here has been done this way in Abbeville, SC since 2006. The out of hours price is stated before anyone is dispatched, the diagnosis is made from readings rather than from symptoms, and the repair is quoted and approved before a part goes in.
The visit follows the same sequence at any hour, because shortening it under time pressure is how the wrong part gets replaced. The technician starts with the description of what happened and when, then eliminates the cheap possibilities before opening anything: thermostat mode and setpoint, filter condition, both breakers, the pull disconnect at the outdoor unit, and the condensate float switch that will deliberately shut a system down when the drain pan fills.
A surprising share of calls end there. A float switch that has tripped because a drain line plugged in July looks identical, from inside the house, to a dead compressor. The difference is a two minute check.
Where the simple causes are ruled out, instruments come out. Line voltage at the contactor, control voltage at the board, capacitance measured against the rating printed on the capacitor, amp draw on the compressor and the condenser fan compared against their nameplate values, then suction and liquid pressures converted to saturation temperatures so superheat and subcooling can be calculated.
A system that will not cool has at least six plausible explanations and they cost wildly different amounts to fix. Naming the expensive one without measuring is either incompetence or something worse, and naming the cheap one without measuring produces a second visit next week.
The readings are written on the invoice. A homeowner who is told the capacitor measured well below its rating, and is shown that rating printed on the side of the part, is in a position to judge the repair rather than to trust it.
The fault is described, the risk to occupants is established, and the visit is priced. Anything involving gas smell or a carbon monoxide alarm is redirected to the utility or emergency services first.
Thermostat, filter, both breakers, the disconnect and the condensate float switch, in that order, before any panel comes off.
Contactor condition, capacitor capacitance against its rating, and amp draw on both motors while the system is actually trying to run.
Pressures converted to saturation temperature, superheat and subcooling calculated, and the temperature split read across the indoor coil.
One flat figure covering the part and the labor, explained before anything is fitted, with any second unrelated fault presented as its own separate line.
The system is run again after the repair and the same readings are retaken, so the fix is demonstrated rather than assumed.
The list below is not exhaustive, but between them these account for the majority of emergency cooling calls. Each one has a characteristic signature that separates it from the others once a meter is involved.
| What the household notices | Common cause | What confirms it |
|---|---|---|
| Outdoor unit hums, fan blade does not turn | Run capacitor failed or well below rating | Measured capacitance against the microfarad value printed on the capacitor |
| Nothing runs outdoors, indoor blower works | Contactor not pulling in, or control voltage lost | Line voltage present at the contactor line side, control voltage absent at the coil |
| System runs constantly, house slowly warms | Low refrigerant charge or a restricted coil | Superheat high with subcooling low, and a narrow temperature split |
| Whole system dead, no response at thermostat | Breaker, pull disconnect, transformer or condensate float switch | Voltage traced back from the board to the disconnect, plus the float switch position |
| Ice on the suction line or the indoor coil | Airflow restriction or low charge | Static pressure across the air handler, then charge readings after a full thaw |
| Loud grinding or shrieking outdoors | Condenser fan motor bearings failing | Amp draw above nameplate and shaft play by hand with power isolated |
A meaningful proportion of calls that sound like a refrigerant problem are an air problem. A filter that has not been changed since spring, a blower wheel loaded with dust, a collapsed section of flexible duct or a closed return can all reduce airflow across the evaporator far enough to drop the coil below freezing.
Adding refrigerant to a system in that state is the classic bad repair. It masks the symptom briefly, overcharges a system that was never low, and leaves the actual restriction in place to do it again. Total external static pressure across the air handler is the reading that separates the two, and it takes about three minutes.
If the coil has iced, switch cooling off and run the fan only. A full thaw is necessary before any refrigerant reading means anything at all, and it is the single most useful thing a household can do before the technician arrives.
Van stock is chosen from failure frequency rather than from cost. There is no value in carrying an obscure component that fails once a decade while being out of stock on the part that accounts for a third of summer calls.
Carried across the common microfarad and voltage ratings for both single and dual capacitors. The most frequent single cause of a cooling failure and a part that costs very little.
Standard pole and coil voltage combinations. A contactor with welded or badly pitted contacts will either refuse to close or refuse to open, and both failures happen at peak load.
With the matching capacitor and mounting hardware. A seized fan motor leaves the compressor rejecting no heat, so it is a same visit repair rather than an order.
Control side components for widely used equipment platforms, plus thermostats, since a surprising number of no cooling calls end at the control rather than at the equipment.
The visit itself carries a night, weekend or holiday rate depending on when the call lands, and you hear that number before anybody leaves the yard. The repair is a second, separate figure, produced once the fault has a name, covering the part and the labor together and approved by you before anything is fitted.
Labor carries a written workmanship warranty. Manufacturer coverage on any supplied part is honored here rather than handed back as a phone number. Where the system turns out to be beyond sensible repair, that is said plainly, but the replacement conversation is deferred to daylight and a proper survey.
Almost every fault in the table above announced itself first as a measurement drifting out of range. A capacitor loses capacitance gradually. A contactor pits a little on every start. A fan motor draws steadily higher current for a season before its bearings give up. None of that is visible or audible from inside the house, and all of it is obvious on a meter in April.
That is the entire argument for a seasonal service visit, and it is not a sales pitch so much as arithmetic. A capacitor fitted during a scheduled spring visit and a capacitor fitted at midnight in August are the same part.
The other half of prevention is the condensate drain, which is responsible for more midsummer shutdowns than most homeowners would believe. Biological growth narrows the line slowly from the moment cooling season starts, and the float switch that eventually trips is doing exactly what it was fitted to do. Clearing that line in spring takes a few minutes. Discovering it during the hottest fortnight of the year costs an emergency visit and a very uncomfortable night.
Neither of those checks requires the equipment to be misbehaving first. They are both worth doing on a system that currently seems perfectly healthy, which is the point at which almost nobody thinks to book them.
Asked during the call
These come up on almost every out of hours call. Reading them in advance is a better use of the information than hearing them while standing in a hot house.
Dispatch is staffed continuously, so the call is answered immediately and a technician is assigned rather than a message being taken. Actual arrival depends on where the queue stands, and during the first serious heat of the season that queue is at its longest.
A realistic window is given on the call rather than an optimistic one. If the wait is four hours, that gets said, because a household that knows it is waiting four hours can make arrangements and a household promised ninety minutes cannot.
It depends on who is in the building. Dangerous indoor heat is a genuine medical risk for infants, elderly occupants and anyone with a cardiac or respiratory condition, and those situations are treated as urgent at any hour.
A healthy household in a building that is uncomfortable but not dangerous is usually better served by a first slot in the morning, which costs less and arrives with a full parts inventory and daylight. The dispatch desk will say which of those two a described situation is.
A failed run capacitor is the single most frequent, followed by a burnt or welded contactor, a seized condenser fan motor, a tripped condensate float switch, and a breaker or pull disconnect that has opened. Between them those account for a very large share of calls.
All five are carried on the van or are resolved on site without parts, which is why most emergency visits end with a running system rather than an order and a return trip.
Classically a failed run capacitor, and it is a situation worth switching the system off for immediately. The compressor may still be trying to run while the condenser fan sits still, which means it is rejecting no heat and heading toward a thermal cutout or worse.
Turn the thermostat off and leave it off until someone looks at it. Spinning the fan blade with a stick to get it started is a widely repeated suggestion and a genuinely dangerous one around live line voltage and a blade that will start under power.
No. Switch cooling off and leave the fan running if the thermostat allows it, which will thaw the coil far faster than doing nothing. Ice means the evaporator has dropped below freezing, which happens when airflow across it is too low or the refrigerant charge is too low.
Running a system in that state pushes liquid refrigerant back toward the compressor, which is what turns an inexpensive airflow problem into a compressor replacement. The thaw also has to be complete before anyone can take useful readings.
Night, weekend and holiday visits carry their own rate, separate from the weekday figure, and that number is given to you during the call itself. The method is the same flat rate approach used in business hours: stated, explained and agreed in advance rather than totalled up from hours on site afterwards.
If the repair itself requires a part, that is quoted as its own approved figure once the fault is identified. Nothing gets fitted without a yes.
Usually. Capacitors across the common ratings, contactors, universal condenser fan motors, transformers, control boards for widely used platforms and thermostats all ride on the van.
Where something has to be ordered, the lead time is given honestly along with whatever can be done to make the building tolerable in the meantime. On a failure during dangerous heat that conversation includes practical advice about which rooms to occupy and how to manage the building until the part arrives.
It helps in two specific situations. If the indoor coil has iced, fan only circulates room air across it and thaws it far faster than switching everything off, which means the technician can take useful readings on arrival instead of waiting an hour. It also keeps air moving through the building, which makes a hot house marginally more tolerable.
It does not help if the fault is the indoor blower itself, and it will not cool the building. The thermostat should be set to off for cooling and fan to on, rather than left calling for cooling with a system that cannot deliver it.
Because that is the first time all season the equipment has been asked for full load current. A compressor starting against high head pressure on a ninety degree afternoon draws far more than it does on a mild evening, and components that are marginal will pass the easy test and fail the hard one.
It is also why the queue is longest during exactly that week, and why a spring service visit is worth so much more than the same visit booked in June.
Occasionally the honest answer at two in the morning is that the equipment has reached the end of its life. When that happens it gets said, but nobody is asked to sign for a replacement in the middle of the night.
Any temporary measure that will get the household through to daylight is done first. The replacement conversation happens the next day with a proper survey behind it, because a decision of that size made under duress is a bad decision even when the conclusion turns out to be right.
An emergency is often the visible end of something slower. These pages cover the parts of the system that most frequently turn out to be responsible.
The dispatch desk will tell you whether what you are describing is urgent, what the visit costs, and what to switch off in the meantime. If it can safely wait until morning, that gets said, and the morning slot gets booked instead.
Coverage runs across Abbeville, SC at every hour, including holidays.